text.skipToContent text.skipToNavigation

Internal Battery Assembly Pack RSPL Kit 5423275

5423275
2378963 2378963-2 FL200027 FL200068 S2378963-3 S2423267
US(超音波診断装置)
その他の超音波
GE HealthCare
日付を選択してください
セカンドオピニオンの承認が必要

承認番号を入力して送信し、商品をカートに追加してください。

承認番号

Please enter approval number

OR

承認番号が分かりませんか?800-437-1171に電話してください。
最初の3つのプロンプトにopt 1を入力し、システムIDを使用できるようにします。

カートに商品を追加し、承認番号なしで注文を送信した場合、
注文が出荷確認できる前にGEから連絡があります。

セカンドオピニオンの承認が必要

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.

希望小売価格 : 価格はお問い合わせください

商品・部品概要

The Internal Battery Assembly is a kit that consists of a battery base, cover, rear rubber, card assembly and battery cell. It is used for ultrasound devices. The Vivid I/Vivid Q ultrasound unit is powered either by its internal battery or by a separate power supply adaptor unit connected to a separate power outlet for any range of 100-240 VAC, 50-60 Hz. The lithium ion battery provides power when an AC power source is interrupted. A battery in the battery bay is standard with Vivid I/Vivid Q. Lithium ion batteries last longer than conventional batteries and do not require replacement as often. It can provide one hour of battery life with a single fully charged battery. The lithium ion technology used is significantly less hazardous to the environment than the lithium metal technology used in any other batteries (such as watch batteries). It has a safety device within it, so it should not be disassembled or altered. Charge and discharge the batteries only when the ambient temperature is between 0° and 65° C (32° and 149° F). Battery insertion or removal should take place only when the system is in "full shutdown" mode. The system has a status icon to display the status of the battery. It is designed to flash special messages for the replacement and re-calibration of the battery. Re-calibration may be required after prolonged usage of the battery, because it’s internal "fuel gauge" (capacity meter) may start to drift. When the battery is out of calibration the system does not read the correct charge stored in the battery. An external battery charger can help to charge the battery in a faster manner. It is recommended to use CH5000V, a standalone desktop smart standard battery charger designed to work with the GE Medical Systems Vivid I smart battery packs. It has the added ability to re-calibrate the fuel gauge on the battery pack and maintain full fuel gauge accuracy throughout the entire life of the battery.

  • 追加機能

    • Can be charged with external adaptor

    対応商品・部品

    Vivid i

    Vivid i

    Vivid q

    Vivid q

    技術仕様

    AttributesValues
    Battery TypeLithium-ion
    Nominal Voltage14.4 Volt
    Capacity6300 mAh
    Operational Voltage11.2 V - 16.8 V
    Cell Temperature:
    Charge0° C to 40° C
    Discharge-20° C to 60° C
    Storage-20° C to 50° C
    Ambient Operating Temperature and Humidity:
    Charge0° C to 40° C, 45% to 85% RH, Non-Condensing
    Discharge-20° C to 50° C, 45% to 85% RH, Non-Condensing

    同等品:

    以下、同等品・アイテムの詳細をご紹介いたします。同等の製品およびハイパーリンクのないアイテムは参照のみを目的としてリストされており、オンラインでは購入できません。

    同等品同等商品・部品の詳細
    2378963 INTERNAL BATTERY PACK-VIVID-I
    2378963-2

    2378963-2

    FL200027

    FL200027

    FL200068

    FL200068

    S2378963-3

    S2378963-3

    S2423267

    S2423267