Flow Transducer BCG 0-160 LPM Electro-Mechanical

1505-3208-000
呼吸ケア
CARESCAPE R860
GE HealthCare
日付を選択してください
セカンドオピニオンの承認が必要

承認番号を入力して送信し、商品をカートに追加してください。

承認番号

Please enter approval number

OR

承認番号が分かりませんか?800-437-1171に電話してください。
最初の3つのプロンプトにopt 1を入力し、システムIDを使用できるようにします。

カートに商品を追加し、承認番号なしで注文を送信した場合、
注文が出荷確認できる前にGEから連絡があります。

セカンドオピニオンの承認が必要

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.

希望小売価格 : 価格はお問い合わせください

商品・部品概要

The Flow Transducer is used in the Engstrom ventilator Breathing Circuit Gas (BCG) module, which is a part of the respiratory care system. A flow sensor is a device used to monitor the air flow rate of a patient and measure the volume of gas dispensed from the O₂ and air channels during inhalation and exhalation. The relative proportion of gas dispensed from each channel is continuously adjusted to accurately control the percentage of O₂ delivered to the patient. The flow sensor is placed in the inlet manifold between the regulator and the flow valve, where the regulator ensures the constant pressure supply to the flow valve. It is a mass flow type sensor, which injects the heat into the flow stream and monitor the temperature rise at the downstream location. The temperature range depends upon the mass flow rate of the flow stream and the specific heat of the gas going through the sensor. There are 3 inspiratory flow sensors used in vent engine. First is the oxygen supply path upstream of the oxygen flow control valves, second is the air supply path upstream of the air flow control valves (both at a nominal 1.72 bar) and third is downstream of both control valves to measure the mixed gas flow rate. The oxygen and air flow sensors will provide a measurement of the mean oxygen concentration delivered and also as calibration for the primary flow control valves. The mixed gas flow sensor will be used to correct the total volume output from both the oxygen and air valves as well as to set the bypass flow rate for the spontaneous patient flow trigger. The same flow sensor is anticipated for use in all three locations. The flow sensor is to be a service module that can be removed and replaced in the ventilator by screws, accessed from one direction only. The sensor is rugged enough so that expected misuse, such as dropping the device will not damage or degrade the performance of the device. Each sensor may be individually calibrated with the data stored on the sensor.

  • 追加機能

    • Easy to install
    • Upper and lower seals never leak
    • RoHS compliant

    対応商品・部品

    CARESCAPE R860

    CARESCAPE R860

    Engstrom

    Engstrom

    Engstrom Carestation

    Engstrom Carestation

    技術仕様

    AttributesValues
    Maximum Pressure178 kPa
    Pressure Range Transducers178 kPa
    Flow Rate0 - 160 L/Min
    Pressure Drop> 4 kPa at 160 SL/min
    Leak Rate> 1 sccm at 200 kPa to Atmosphere
    Burst Pressure1000 kPa
    Proof Pressure400 kPa for 60 Seconds
    Weight> 0.5 kg